Breaker

You are running a Trial version of Nop JCarousel

"Breaker ပစ္စည်းမျိုးစုံကို Brand အမျိုးအစား စုံလင်စွာဖြင့် စျေးနှုန်းမှန်ကန်စွာရောင်းချပေးနေပါပြီ...

အသေးစိတ် သိရှိလိုပါက 09 269300002 / 09 269300001 သို့ ဆက်သွယ်စုံစမ်းမေးမြန်းနိုင်ပါတယ်....."

View as Grid List
Sort by
Display per page

Lian Xiang Breaker Box

Breaker Box (Matel)
16,500 Ks

RR Global (Triple) Three Pole Miniature Circuit Breakers (MCB)

(Triple) Three Pole MCB
9,000 Ks

RR Global Double Pole Miniature Circuit Breakers (MCB)

Double Pole MCB
5,630 Ks

RR Global Four Pole Miniature Circuit Breakers (MCB)

Four Pole MCB
8,700 Ks

RR Global Moulded Case Circuit Breakers (MCCB)

MCCB
51,000 Ks

RR Global ON LOAD CHANGE OVER (WITH ENCLOSURE)

CHANGE OVER
103,100 Ks

RR Global Single Pole Miniature Circuit Breakers (MCB)

Single Pole MCB
2,700 Ks

Siemens Breaker - 2 POLE RCBO

RCBO 2 POLE
42,000 Ks

Siemens Breaker - 2 POLE RCCB

RCCB's, TYPE AC, INSTANTANEOUS, 125…230V AC; 50…60HZ N CONNECTION, RIGHT
56,500 Ks

Siemens Breaker - 4 POLE RCCB

RCCB's, TYPE AC, INSTANTANEOUS, 230…400V AC; 50…60HZ N CONNECTION, RIGHT
103,000 Ks

Siemens Breaker 1POLE MCB

MCB's 7.5KA, C (5SL6 Series)
5,200 Ks

Siemens Breaker 2 POLE MCCB 3VM (lcu=25kA)

MCCB 3VM (lcu=25kA)
81,000 Ks

Siemens Breaker 2POLE MCB

MCB's 7.5KA, C (5SL6 Series)
15,500 Ks

Siemens Breaker 2POLE MCB

MCB's, 7.5KA, C (5SL6 Series)
15,500 Ks

Siemens Breaker 3 POLE MCCB 3VM (lcu=36kA)

MCCB 3VM (lcu=36kA)
288,500 Ks

Siemens Breaker 3 POLE MCCB 3VM (lcu=25kA)

MCCB 3VM (lcu=25kA)
83,500 Ks

Siemens Breaker 3POLE MCB

MCB's 7.5KA, C (5SL6 Series)
27,200 Ks

Siemens Breaker 4 POLE MCCB 3VM (lcu=25kA)

MCCB 3VM (lcu=25kA)
111,000 Ks

Siemens Breaker 4 POLE MCCB 3VM (lcu=36kA)

MCCB 3VM (lcu=36kA)
435,000 Ks

Siemens Breaker 4POLE MCB

MCB's 7.5KA, C (5SL6 Series)
38,000 Ks

Consumer Unit-Din Type (MCB Breaker)

Pole:                            1Pole
6,620 Ks

Consumer Unit-Din Type (MCB Breaker)

Pole:                            1Pole
28,183 Ks

Din Type (RCBO Breaker)

Pole: 2Pole
38,799 Ks

Schneider 4Pole, 30A, 15kA, EZC100N, MCCB

Molded/Moulded Case Circuit Breaker (MCCB) - Schneider Electric / Merlin Gerin (EasyPact EZC) - EZC100N 4P 30A - 4 poles (4P3d) - Rated current 30A - Rated voltage 250Vdc - Short circuit breaking capacity (Icu) 15kA (400-415Vac) - Thermal-Magnetic (fixed) trip unit (TMD) - Lug connection
233,800 Ks

Schneider 4Pole, 160A, 25kA, EZC250N, MCCB

Molded/Moulded Case Circuit Breaker (MCCB) - Schneider Electric / Merlin Gerin (EasyPact EZC) - EZC250N 4P 160A - 4 poles (4P3d) - Rated current 160A - Rated voltage 250Vdc - Short circuit breaking capacity (Icu) 25kA (400-415Vac) - Thermal-Magnetic (fixed) trip unit (TMD) - Lug connection
410,000 Ks

Schneider 2Pole, 30A, 30kA, EZC100H, MCCB

Molded/Moulded Case Circuit Breaker (MCCB) - Schneider Electric / Merlin Gerin (EasyPact EZC) - EZC100H 2P 30A - 2 poles (2P2d) - Rated current 30A - Rated voltage 250Vdc - Short circuit breaking capacity (Icu) 30kA (400-415Vac) - Thermal-Magnetic (fixed) trip unit (TMD) - Lug connection
114,800 Ks

Schneider Breaker 4Pole, 80A, 15kA, EZC100N, MCCB

Molded/Moulded Case Circuit Breaker (MCCB) - Schneider Electric / Merlin Gerin (EasyPact EZC) - EZC100N 4P 80A - 4 poles (4P3d) - Rated current 80A - Rated voltage 250Vdc - Short circuit breaking capacity (Icu) 15kA (400-415Vac) - Thermal-Magnetic (fixed) trip unit (TMD) - Lug connection
245,500 Ks

Schneider 4Pole, 60A, 15kA, EZC100N, MCCB

Molded/Moulded Case Circuit Breaker (MCCB) - Schneider Electric / Merlin Gerin (EasyPact EZC) - EZC100N 4P 60A - 4 poles (4P3d) - Rated current 60A - Rated voltage 250Vdc - Short circuit breaking capacity (Icu) 15kA (400-415Vac) - Thermal-Magnetic (fixed) trip unit (TMD) - Lug connection
237,500 Ks

SCHNEIDER ELECTRIC 2Pole, 25A, 30kA, EZC100H, MCCB

Molded/Moulded Case Circuit Breaker (MCCB) - Schneider Electric / Merlin Gerin (EasyPact EZC) - EZC100H 2P 25A - 2 poles (2P2d) - Rated current 25A - Rated voltage 250Vdc - Short circuit breaking capacity (Icu) 30kA (400-415Vac) - Thermal-Magnetic (fixed) trip unit (TMD) - Lug connection
114,800 Ks

Schneider SHUNT TRIP EZC100 200-277VAC

Shunt trip release coil (SHT) - Schneider Electric / Merlin Gerin - Control voltage 200Vac-277Vac
149,700 Ks

Schneider SHUNT TRIP EZC250 200-240VAC

123,200 Ks

Schneider 2Pole, 32A, 6kA, Easy9, MCB

Miniature circuit breaker, Easy9, 2P, 32 A, C curve, 6000 A
27,300 Ks

Schneider Breaker 1Pole, 10A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 10 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
8,700 Ks

Schneider Breaker 1Pole, 6A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 6 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
8,700 Ks

Schneider Breaker 1Pole, 16A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 16 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
8,700 Ks

Schneider Breaker 1Pole, 20A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 20 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
8,700 Ks

Schneider Breaker 1Pole, 25A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 25 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
10,400 Ks

Schneider Breaker 1Pole, 32A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 32 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
10,400 Ks

Schneider Breaker 1Pole, 40A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 40 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
10,400 Ks

Schneider Breaker 1Pole, 50A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 50 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
16,500 Ks

Schneider Breaker 1Pole, 63A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 1P number of protected poles 1 [In] rated current 63 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to IEC 60898-1 10000 A Icn at 127 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
16,500 Ks

Schneider Breaker 2Pole, 6A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 6 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
25,400 Ks

Schneider Breaker 2Pole, 10A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 6 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
230 Ks

Schneider Breaker 2Pole, 16A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 16 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
25,400 Ks

Schneider Breaker 2Pole, 20A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 20 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
25,400 Ks

Schneider Breaker 2Pole, 25A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 25 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
27,300 Ks

Schneider Breaker 2Pole, 40A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 40 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
27,300 Ks

Schneider Breaker 2Pole, 50A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 2P number of protected poles 2 [In] rated current 40 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
36,000 Ks

Schneider Breaker 3Pole, 6A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 6 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
42,800 Ks

Schneider Breaker 3Pole, 10A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 10 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
42,800 Ks

Schneider Breaker 3Pole, 16A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 16 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
42,800 Ks

Schneider Breaker 3Pole, 20A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 20 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
42,800 Ks

Schneider Breaker 3Pole, 25A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 25 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
46,200 Ks

Schneider Breaker 3Pole, 32A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 25 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
46,200 Ks

Schneider Breaker 3Pole, 40A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 40 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
46,200 Ks

Schneider Breaker 3Pole, 50A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 50 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
64,300 Ks

Schneider Breaker 3Pole, 63A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 3P number of protected poles 3 [In] rated current 63 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
64,300 Ks

Schneider Breaker 4Pole, 6A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 6 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
63,100 Ks

Schneider Breaker 4Pole, 10A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 10 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
63,100 Ks

Schneider Breaker 4Pole, 16A, 6kA, Easy9, MCB

range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 16 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
63,100 Ks

Schneider Breaker 4Pole, 20A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 20 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
63,100 Ks

Schneider Breaker 4Pole, 25A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 25 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
66,800 Ks

Schneider Breaker 4Pole, 32A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 32 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
66,800 Ks

Schneider Breaker 4Pole, 40A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 40 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
66,800 Ks

Schneider Breaker 4Pole, 50A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 50 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
97,000 Ks

Schneider Breaker 4Pole, 63A, 6kA, Easy9, MCB

Main range Easy9 device application Distribution product or component type Miniature circuit-breaker device short name Easy9 MCB Poles 4P number of protected poles 4 [In] rated current 63 A network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 10000 A Icn at 220 V AC 50/60 Hz conforming to IEC 60898-1 6000 A Icn at 400 V AC 50/60 Hz conforming to IEC 60898-1 suitability for isolation Yes conforming to IEC 60898-1
97,000 Ks

Schneider Breaker 2 Pole, 25A, 30mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 25 A network type AC earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 25 A
71,900 Ks

Schneider Breaker 2 Pole, 40A, 30mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 40 A network type AC earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 40 A
73,400 Ks

Schneider Breaker 2 Pole, 63A, 30mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 63 A network type AC earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 63 A
89,900 Ks

Schneider Breaker 2 Pole, 25A, 100mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 25 A network type AC earth-leakage sensitivity 100 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 25 A
79,200 Ks

Schneider Breaker 2 Pole, 40A, 100mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 40 A network type AC earth-leakage sensitivity 100 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 40 A
80,700 Ks

Schneider Breaker 2 Pole, 63A, 100mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 63 A network type AC earth-leakage sensitivity 100 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 63 A
98,900 Ks

Schneider Breaker 2 Pole, 25A, 300mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 25 A network type AC earth-leakage sensitivity 300 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 25 A
75,500 Ks

Schneider Breaker 2 Pole, 40A, 300mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 40 A network type AC earth-leakage sensitivity 300 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 40 A
77,000 Ks

Schneider Breaker 2 Pole, 63A, 300mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 2P neutral position Left [In] rated current 63 A network type AC earth-leakage sensitivity 300 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 63 A
94,400 Ks

Schneider Breaker 4 Pole, 25A, 30mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 25 A network type AC earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 25 A
129,500 Ks

Schneider Breaker 4 Pole, 40A, 30mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 40 A network type AC earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 40 A
131,900 Ks

Schneider Breaker 4 Pole, 63A, 30mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 63 A network type AC earth-leakage sensitivity 30 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 63 A
161,700 Ks

Schneider Breaker 4 Pole, 25A, 100mA, Easy9, RCCB

142,400 Ks

Schneider Breaker 4 Pole, 40A, 100mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 40 A network type AC earth-leakage sensitivity 100 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 40 A
145,200 Ks

Schneider Breaker 4 Pole, 63A, 100mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 63 A network type AC earth-leakage sensitivity 100 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 63 A
155,700 Ks

Schneider Breaker 4 Pole, 25A, 300mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 25 A network type AC earth-leakage sensitivity 300 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 25 A
135,900 Ks

Schneider Breaker 4 Pole, 40A, 300mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 40 A network type AC earth-leakage sensitivity 300 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 40 A
138,600 Ks

Schneider Breaker 4 Pole, 63A, 300mA, Easy9, RCCB

Main range of product Easy9 product or component type Residual current circuit breaker (RCCB) device short name Easy9 RCCB Poles 4P neutral position Left [In] rated current 63 A network type AC earth-leakage sensitivity 300 mA earth-leakage protection time delay Instantaneous earth-leakage protection class Type AC rated breaking and making capacity 500 A rated conditional short-circuit current Easy9 MCB: 6000 A 63 A
169,800 Ks

Schneider Breaker 2Pole, 15A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 2P protected poles description 2t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 15 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
114,800 Ks

Schneider Breaker 2Pole, 40A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 2P protected poles description 2t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
118,200 Ks

Schneider Breaker 2Pole, 100A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 2P protected poles description 2t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
121,600 Ks

Schneider Breaker 2Pole, 50A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 2P protected poles description 2t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
110,500 Ks

Schneider Breaker 2Pole, 80A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 2P protected poles description 2t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
121,600 Ks

Schneider Breaker 2Pole, 125A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 2P protected poles description 2t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
292,600 Ks

Schneider Breaker 3Pole, 16A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 16 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
108,700 Ks

Schneider Breaker3Pole, 20A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664--1 3 conforming to IEC 947-1
108,700 Ks

Schneider Breaker 3Pole, 25A, 10KA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
108,700 Ks

Schneider Breaker 3Pole, 30A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 30 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
112,000 Ks

Schneider Breaker 3Pole, 32A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 32 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
112,000 Ks

Schneider Breaker 3Pole, 40A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
112,000 Ks

Schneider Breaker 3Pole, 50A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
112,000 Ks

Schneider Breaker 3Pole, 60A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 60 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
112,000 Ks

Schneider Breaker 3Pole, 80A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
115,200 Ks

Schneider Breaker 3Pole 100A, 10kA, EZC100F, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100F circuit breaker name Easypact EZC100F device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code F breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 3.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
115,200 Ks

Schneider Breaker 3Pole, 15A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 15 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
186,600 Ks

Schneider Breaker 3Pole, 20A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
186,600 Ks

Schneider Breaker 3Pole, 25A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
186,600 Ks

Schneider Breaker 3Pole, 30A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 30 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
199,200 Ks

Schneider Breaker 3Pole, 32A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 32 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
199,200 Ks

Schneider Breaker

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
199,200 Ks

Schneider Breaker 3Pole, 50A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
199,200 Ks

Schneider Breaker 3Pole, 60A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 60 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
199,200 Ks

Schneider Breaker 3Pole, 75A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 75 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
202,300 Ks

Schneider Breaker 3Pole, 80A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
202,300 Ks

Schneider Breaker 3Pole, 100A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
202,300 Ks

Schneider Breaker 3Pole, 125A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
292,900 Ks

Schneider Breaker 3Pole, 125A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
292,900 Ks

Schneider Breaker 3Pole, 150A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 150 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
292,900 Ks

Schneider Breaker 3Pole, 160A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
292,900 Ks

Schneider Breaker 3Pole, 175A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 175 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
292,900 Ks

Schneider Breaker 3Pole, 200A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 200 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
322,200 Ks

Schneider Breaker 3Pole, 225A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 225 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
322,200 Ks

Schneider Breaker 3Pole, 250A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
322,200 Ks

Schneider Breaker 3Pole, 20A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
120,800 Ks

Schneider Breaker 3Pole, 25A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
120,800 Ks

Schneider Breaker 3Pole, 30A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 30 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
120,800 Ks

Schneider Breaker 3Pole, 32A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 30 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
124,400 Ks

Schneider Breaker 3Pole, 40A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
124,400 Ks

Schneider Breaker 3Pole, 50A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
124,400 Ks

Schneider Breaker 3Pole, 40A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
124,400 Ks

Schneider Breaker 3Pole, 60A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 60 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
124,400 Ks

Schneider Breaker 3Pole, 80A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
128,000 Ks

Schneider Breaker 3Pole, 100A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 50 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
128,000 Ks

Schneider Breaker 3Pole, 125A, 30kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
344,200 Ks

Schneider Breaker 3Pole, 150A, 30kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 150 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
344,200 Ks

Schneider Breaker 3Pole, 160A, 30kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
344,200 Ks

Schneider Breaker 3Pole, 175A, 30kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 175 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
344,200 Ks

Schneider Breaker 3Pole, 200A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 200 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
378,600 Ks

Schneider Breaker 3Pole, 225A, 30kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 225 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
378,600 Ks

Schneider Breaker 3Pole, 250A, 30kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 3P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
378,600 Ks

Schneider Breaker 4Pole, 15A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 15 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
233,800 Ks

Schneider Breaker 4Pole, 20A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
233,800 Ks

Schneider Breaker 4Pole, 25A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
233,800 Ks

Schneider Breaker 4Pole, 30A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 30 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
237,500 Ks

Schneider Breaker 4Pole, 50A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
237,500 Ks

Schneider Breaker 4Pole, 75A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 75 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
245,500 Ks

Schneider Breaker 4Pole, 100A, 15kA, EZC100N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100N circuit breaker name Easypact EZC100N device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 10 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 5 kA Icu at 125 V DC 1P conforming to IEC 60947-2 5 kA Icu at 250 V DC 2P conforming to IEC 60947-2 5 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 125 V DC conforming to IEC 60947-2 2.5 kA at 250 V DC conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 9 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
245,500 Ks

Schneider Breaker4Pole, 125A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
410,000 Ks

Schneider Breaker 4Pole, 175A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 175 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
410,000 Ks

Schneider Breaker 4Pole, 225A, 25kA, EZC250N, MCCB 421,500.00 CN 70

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 225 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
451,000 Ks

Schneider Breaker 4Pole, 225A, 25kA, EZC250N, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250N circuit breaker name Easypact EZC250N device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code N breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
451,000 Ks

Schneider Breaker 4Pole, 15A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 15 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
181,200 Ks

Schneider Breaker 4Pole, 20A, 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
181,200 Ks

Schneider Breaker 4Pole, 25A , 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 20 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
181,200 Ks

Schneider Breaker 4Pole, 30A , 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 30 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
181,200 Ks

Schneider Breaker 4Pole, 40A , 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
186,600 Ks

Schneider Breaker 4Pole, 50A , 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
186,600 Ks

Schneider Breaker 4Pole, 60A , 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 60 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
186,600 Ks

Schneider Breaker 4Pole, 80A , 30kA, EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
186,600 Ks

Schneider Breaker 4Pole, 100A, 30kA , EZC100H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC100H circuit breaker name Easypact EZC100H device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-2 10 kA Icu at 250 V DC 2P conforming to IEC 60947-2 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 125 V DC conforming to IEC 60947-2 5 kA at 250 V DC conforming to IEC 60947-2 5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 380...400 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 7.5 kA at 415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
192,000 Ks

Schneider Breaker 4Pole, 125A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
428,500 Ks

Schneider Breaker 4Pole, 160A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 4P protected poles description 3t network type DC AC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
451,000 Ks

Schneider Breaker 4Pole, 200A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 200 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
451,000 Ks

Schneider Breaker 4Pole, 225A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 225 A at 50 °C protection type Overload protection Short-circuit protection pollution degree 3 conforming to IEC 60947
451,000 Ks

Schneider Breaker 4Pole, 250A, 36kA, EZC250H, MCCB

Main range of product EasyPact product or component type Circuit breaker device short name Easypact EZC250H circuit breaker name Easypact EZC250H device application Distribution poles description 4P protected poles description 3t network type AC DC network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2 breaking capacity code H breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 125 V DC 1P conforming to IEC 60947-2 30 kA Icu at 250 V DC 2P conforming to IEC 60947-2 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 125 V DC conforming to IEC 60947-2 15 kA at 250 V DC conforming to IEC 60947-2 12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 18 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 42.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 50 °C protection type Short-circuit protection Overload protection pollution degree 3 conforming to IEC 60947
496,200 Ks

Schneider Breaker 3pole, 16A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 16 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
174,200 Ks

Schneider Breaker 3pole, 25A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
174,200 Ks

Schneider Breaker 3pole, 32A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 32 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
177,500 Ks

Schneider Breaker 3pole, 40A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
174,200 Ks

Schneider Breaker 3Pole, 50A, 25kA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
179,500 Ks

Schneider Breaker 3Pole, 63A, 25kA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 63 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
179,500 Ks

Schneider Breaker 3Pole, 80A, 25kA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
184,700 Ks

Schneider Breaker 3Pole, 100A, 25kA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
184,700 Ks

Schneider Breaker 3Pole, 100A, 25kA, CVS160B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
239,600 Ks

Schneider Breaker 3Pole, 125A, 25kA, CVS160B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
239,600 Ks

Schneider Breaker 3Pole, 160A, 25kA, CVS160B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
335,300 Ks

Schneider Breaker 3Pole, 250A, 25kA, CVS250B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250B device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
335,300 Ks

Schneider Breaker 3pole, 16A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 16 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
209,100 Ks

Schneider Breaker 3pole, 25A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
209,100 Ks

Schneider Breaker 3pole, 32A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 32 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
209,100 Ks

Schneider Breaker 3pole, 40A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
209,100 Ks

Schneider Breaker 3Pole, 50A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
215,300 Ks

Schneider Breaker 3Pole, 63A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 63 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
215,300 Ks

Schneider Breaker 3Pole, 80A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
221,700 Ks

Schneider Breaker 3Pole, 100A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
221,700 Ks

Schneider Breaker 3Pole, 125A, 36KA, CVS160F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
261,300 Ks

Schneider Breaker 3Pole, 160A, 36KA, CVS160F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
287,500 Ks

Schneider Breaker 3Pole, 200A, 36KA, CVS250F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 200 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
402,400 Ks

Schneider Breaker 3Pole, 250A, 36KA, CVS250F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250F device application Distribution poles description 3P protected poles description 3d Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
402,400 Ks

Schneider Breaker 4Pole, 16A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 16 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
243,900 Ks

Schneider Breaker 4Pole, 25A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
243,900 Ks

Schneider Breaker 4Pole, 32A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 32 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
243,900 Ks

Schneider Breaker 4Pole, 40A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
243,900 Ks

Schneider Breaker 4Pole, 50A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
251,200 Ks

Schneider Breaker 4Pole, 63A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 63 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
251,200 Ks

Schneider Breaker 4Pole, 80A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
258,500 Ks

Schneider Breaker 4Pole, 100A, 25KA, CVS100B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
258,500 Ks

Schneider Breaker 4Pole, 125A, 25KA, CVS160B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
311,400 Ks

Schneider Breaker 4Pole, 160A, 25KA, CVS160B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
325,500 Ks

Schneider Breaker 4Pole, 200A, 25KA, CVS250B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 200 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
469,500 Ks

Schneider Breaker 4Pole, 250A, 25KA, CVS250B, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250B device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code B network type AC [Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
469,500 Ks

Schneider Breaker 4Pole, 16A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 16 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
282,200 Ks

Schneider Breaker 4Pole, 25A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 25 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
282,200 Ks

Schneider Breaker 4Pole, 32A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 32 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
282,200 Ks

Schneider Breaker 4Pole, 40A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 40 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
282,200 Ks

Schneider Breaker 4Pole, 50A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 50 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
290,700 Ks

Schneider Breaker 4Pole, 63A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 63 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
290,700 Ks

Schneider Breaker 4Pole, 80A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 80 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
299,200 Ks

Schneider Breaker 4Pole, 100A, 36KA, CVS100F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS100F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 100 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 100 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
299,200 Ks

Schneider Breaker 4Pole, 125A, 36KA, CVS160F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 125 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
339,700 Ks

Schneider Breaker 4Pole, 160A, 36KA, CVS160F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS160F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 160 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 160 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
339,700 Ks

Schneider Breaker 4Pole, 200A, 36KA, CVS250F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 200 A at 40 °C protection type Short-circuit protection (magnetic) Overload protection (thermal)
516,400 Ks

Schneider Breaker 4Pole, 250A, 36KA, CVS250F, MCCB

Main range of product Easypact CVS100...250 product or component type Circuit breaker device short name CVS250F device application Distribution poles description 4P protected poles description 3d neutral position Left Earth leakage protection (Vigi add on) Without [In] rated current 250 A at 40 °C breaking capacity code F network type AC [Icu] Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 utilisation category Category A trip unit name TM-D trip unit technology Thermal-magnetic trip unit rating 250 A at 40 °C protection type Overload protection (thermal) Short-circuit protection (magnetic)
516,400 Ks

Schneider Breaker 1Pole, 6A, 10kA, Acti9, MCB

Acti9 iC40 Miniature Circuit Breakers up to 40 A
13,000 Ks

Schneider Breaker 1Pole, 10A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 10 A network type DC AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards IEC 60947-2 EN 60898-1 IEC 60898-1 EN 60947-2
13,000 Ks

Schneider Breaker 1Pole, 16A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 16 A network type AC DC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards EN 60898-1 IEC 60947-2 IEC 60898-1 EN 60947-2
13,000 Ks

Schneider Breaker 1Pole, 20A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 20 A network type AC DC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2
13,000 Ks

Schneider Breaker 1Pole, 25A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 25 A network type AC DC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2
13,000 Ks

Schneider Breaker 1Pole, 32A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 32 A network type AC DC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards EN 60947-2 IEC 60947-2 EN 60898-1 IEC 60898-1
13,000 Ks

Schneider Breaker 1Pole, 40A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 40 A network type AC DC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards EN 60898-1 IEC 60947-2 IEC 60898-1 EN 60947-2
13,000 Ks

Schneider Breaker 1Pole, 50A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 50 A network type DC AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards IEC 60898-1 IEC 60947-2 EN 60947-2 EN 60898-1
43,800 Ks

Schneider Breaker 1Pole, 63A, 10kA, Acti9, MCB

Main device application Distribution range Acti 9 product name Acti 9 iC60 product or component type Miniature circuit-breaker device short name IC60N poles description 1P number of protected poles 1 [In] rated current 63 A network type DC AC trip unit technology Thermal-magnetic curve code C breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 standards IEC 60947-2 EN 60947-2 IEC 60898-1 EN 60898-1
43,800 Ks

Schneider Breaker 1Pole, 80A, 10kA, Acti9, MCB

Main range of product C120 range Acti 9 product name C120 product or component type Miniature circuit-breaker device short name C120N device application Distribution poles description 1P number of protected poles 1 [In] rated current 80 A at 30 °C network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 suitability for isolation Yes conforming to IEC 60947-2
108,500 Ks

Schneider Breaker 1Pole, 100A, 10kA, Acti9, MCB

Main range of product C120 range Acti 9 product name C120 product or component type Miniature circuit-breaker device short name C120N device application Distribution poles description 1P number of protected poles 1 [In] rated current 100 A at 30 °C network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 suitability for isolation Yes conforming to IEC 60947-2
124,700 Ks

Schneider Breaker 1Pole, 125A, 10kA, Acti9, MCB

Main range of product C120 range Acti 9 product name C120 product or component type Miniature circuit-breaker device short name C120N device application Distribution poles description 1P number of protected poles 1 [In] rated current 125 A at 30 °C network type AC trip unit technology Thermal-magnetic curve code C breaking capacity 3 kA Icu at 380...415 V AC 50/60 Hz IT conforming to EN/IEC 60947-2 20 kA Icu at 130 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12 V DC conforming to EN/IEC 60947-2 15 kA Icu at 125 V DC conforming to EN/IEC 60947-2 10 kA Icu at <= 144 V DC conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 suitability for isolation Yes conforming to IEC 60947-2
194,300 Ks

UKK 80A Terminal Block

11,600 Ks